Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Anesthesia and Pain Medicine ; : 240-244, 2013.
Article in English | WPRIM | ID: wpr-135283

ABSTRACT

BACKGROUND: Optiscope PM201 is a newly developed video stylet device. In comparison to the Macintosh laryngoscope, it offers a significantly improved laryngeal view and facilitates endotracheal intubation. The present study was performed to compare the general efficiency and the cardiovascular responses generated by Macintosh and Optiscope PM201 systems during endotracheal intubation. METHODS: This study included 66 patients with American Society of Anesthesiologists physical status class I or II requiring tracheal intubation for general anesthesia. All patients were randomly allocated into two groups: OptiScope PM201 (group O) and Macintosh (group M). Systolic, mean and diastolic blood pressure (SBP, MBP, DBP) and heart rate (HR) were recorded just prior to intubation (Tbase), 1 minute after intubation (T0), and over the following 10 minutes at 5 minute intervals 5, 10 minutes after intubation (T1, T2). Time for intubation and degree of sore throat were also recorded. RESULTS: There were no significant differences in SBP, MBP, DBP, HR, incidence of sore throat and time for intubation between both groups. The incidence of oral bleeding was none in patient in the Group O versus 1 in group M (P = 0.306). CONCLUSIONS: OptiScope PM201 video system in endotracheal intubation did not increase hemodynamic changes and postoperative airway complications comparing to the use of Macintosh laryngoscope.


Subject(s)
Humans , Anesthesia, General , Blood Pressure , Heart Rate , Hemodynamics , Hemorrhage , Incidence , Intubation , Intubation, Intratracheal , Laryngoscopes , Pharyngitis
2.
Anesthesia and Pain Medicine ; : 240-244, 2013.
Article in English | WPRIM | ID: wpr-135282

ABSTRACT

BACKGROUND: Optiscope PM201 is a newly developed video stylet device. In comparison to the Macintosh laryngoscope, it offers a significantly improved laryngeal view and facilitates endotracheal intubation. The present study was performed to compare the general efficiency and the cardiovascular responses generated by Macintosh and Optiscope PM201 systems during endotracheal intubation. METHODS: This study included 66 patients with American Society of Anesthesiologists physical status class I or II requiring tracheal intubation for general anesthesia. All patients were randomly allocated into two groups: OptiScope PM201 (group O) and Macintosh (group M). Systolic, mean and diastolic blood pressure (SBP, MBP, DBP) and heart rate (HR) were recorded just prior to intubation (Tbase), 1 minute after intubation (T0), and over the following 10 minutes at 5 minute intervals 5, 10 minutes after intubation (T1, T2). Time for intubation and degree of sore throat were also recorded. RESULTS: There were no significant differences in SBP, MBP, DBP, HR, incidence of sore throat and time for intubation between both groups. The incidence of oral bleeding was none in patient in the Group O versus 1 in group M (P = 0.306). CONCLUSIONS: OptiScope PM201 video system in endotracheal intubation did not increase hemodynamic changes and postoperative airway complications comparing to the use of Macintosh laryngoscope.


Subject(s)
Humans , Anesthesia, General , Blood Pressure , Heart Rate , Hemodynamics , Hemorrhage , Incidence , Intubation , Intubation, Intratracheal , Laryngoscopes , Pharyngitis
SELECTION OF CITATIONS
SEARCH DETAIL